<?xml version="1.0" encoding="UTF-8"?>
<rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns="http://purl.org/rss/1.0/" xmlns:dc="http://purl.org/dc/elements/1.1/">
  <channel rdf:about="https://sci.ldubgd.edu.ua/jspui/handle/123456789/8359">
    <title>DSpace Collection:</title>
    <link>https://sci.ldubgd.edu.ua/jspui/handle/123456789/8359</link>
    <description />
    <items>
      <rdf:Seq>
        <rdf:li rdf:resource="https://sci.ldubgd.edu.ua/jspui/handle/123456789/8400" />
        <rdf:li rdf:resource="https://sci.ldubgd.edu.ua/jspui/handle/123456789/8399" />
      </rdf:Seq>
    </items>
    <dc:date>2026-04-05T19:54:50Z</dc:date>
  </channel>
  <item rdf:about="https://sci.ldubgd.edu.ua/jspui/handle/123456789/8400">
    <title>Чисельне моделювання впливу конструктивних параметрів протипожежних карнизів на поширення пожежі фасадом висотних будинків</title>
    <link>https://sci.ldubgd.edu.ua/jspui/handle/123456789/8400</link>
    <description>Title: Чисельне моделювання впливу конструктивних параметрів протипожежних карнизів на поширення пожежі фасадом висотних будинків
Authors: Яковчук, Роман Святославович; Кагітін, О.І.; Балло, Я.В.</description>
    <dc:date>2021-01-01T00:00:00Z</dc:date>
  </item>
  <item rdf:about="https://sci.ldubgd.edu.ua/jspui/handle/123456789/8399">
    <title>FDS simulation of fire spreading on façade heat insulating system</title>
    <link>https://sci.ldubgd.edu.ua/jspui/handle/123456789/8399</link>
    <description>Title: FDS simulation of fire spreading on façade heat insulating system
Authors: Яковчук, Роман Святославович; Kuzyk / Кузик, Andriy / Андрій; Kagitin / Кагітін, Olexander / Олександр; Ivanusa / Івануса, Andriy / Андрій; Yemelyanenko / Ємельяненко, Sergiy / Сергій
Abstract: The main purpose of this work was to determine the parameters of the fire test of the&#xD;
exterior wall construction with facade heat insulation and plaster to spread the fire by FDS&#xD;
simulation, to reproduce the real conditions of fire test and to verify the developed model by&#xD;
comparing the obtained data with experimental results. Satisfactory error was obtained when&#xD;
measuring temperatures experimentally and by computer simulation during experiments.&#xD;
An experimental study of the spread of fire on the surface of external walls with facade insulation&#xD;
and computer simulation of full-scale tests using computer methods of gas hydrodynamics.&#xD;
Using computer simulation of the parameters of the fire test of the facade insulation system for&#xD;
the spread of fire in the FDS environment, numerical and graphical indicators were obtained that&#xD;
characterize the process of occurrence, spread and development of fire by the surface of the&#xD;
facade insulation system. Computer modelling of fire dynamics using FDS numeric tool was&#xD;
implemented and results obtained were compared with experimental data in order to check&#xD;
possibility of use of appropriate software for the reproduction of real conditions of fires at&#xD;
residential buildings.</description>
    <dc:date>2021-01-01T00:00:00Z</dc:date>
  </item>
</rdf:RDF>
