dc.date.issued2020-
dc.identifier.citationYuriy Rudyk, Victor Kuts and Oleg Nazarovets Means for measuring control of impulsive overvoltage caused by thunderstorms, 2019 International Scientific-Practical Conference Problems of Infocommunications. Science and Technology (PIC S&T), Kyiv, Ukraine, 2019, pp.694-697. DOI: 10.1109/PICST47496.2019.9061219uk
dc.identifier.isbn978-1-7281-4182-4-
dc.identifier.urihttps://sci.ldubgd.edu.ua/jspui/handle/123456789/6959-
dc.description.abstractThe analysis of national normative and technical requirements of the lightning protection systems shows the necessity of additional protecting measures from the direct strike of lightning or voltage induction by a remote discharge by determining protective devices choice and charts of their settings. The protection of information and communication systems and their electronic devices components is particularly dependent on the thunderstorms in the environment. Methods of calculation and protecting schemes from impulsive overvoltage recommended by international standards of IEC, are more hard and reliable. Therefore, it is proposed to apply in the circuits of protection against impulse overvoltage means of measurements. The proposed means for measuring control detects and fixes impulse deviations from sinusoidal form of network voltage. On this basis the application schemes of control devices for impulsive overvoltage are complemented, that substantially reduces the risk of fires and electronic device damage from thunderstorm origin. Implementation in the field of operation and maintenance of electronic and telecommunication equipment is proposed.uk
dc.description.sponsorshipLLC Trading House "Security Systems" http://tdsb.com.ua/uk
dc.language.isoenuk
dc.publisherIEEEuk
dc.subjectimpulse; measurement; amplitude; duration; overvoltage; lightning protection; electronic devices; hazard; damageuk
dc.titleMeans for measuring control of impulsive overvoltage caused by thunderstormsuk
dc.title.alternative2019 International Scientific-Practical Conference Problems of Infocommunications. Science and Technology (PIC S&T)uk
dc.typeArticleuk
dcterms.referencesT. Kisielewicz; G. Battista Lo Piparo; and C. Mazzetti, “Probability of surge protective device systems to reduce the risk of failure of apparatus due direct flashes to overhead low voltage lines,” in Proceedings of the 33th International Conference on Lightning Protection (ICLP), Estoril, Portugal, 2016.-
dcterms.referencesY. Rudyk, S. Solionyy, Analisys of protecting schemes of electrical devices from impulsive overvoltage caused by thunderstorms and commutations, Pozhezhna bezpeka, no.17, pp.20-25, 2017-
dcterms.referencesGOST 13109-97. “Elektricheskaya energiya. Sovmestimost' tekhnicheskikh sredstv elektromagnitnaya. Normy kachestva elektricheskoi energii v sistemakh elektrosnabzheniya obshchego naznacheniya [Electrical energy. Compatibility of technical means electromagnetical. Quality norms of electrical energy in general purpose grids],” Moskow, Russia, Standards Publishers, 1997. (In Russian).-
dcterms.referencesPN-EN 50160:1998. „Parametry napięcia zasilającego w publicznych sieciach [Parameters of supply voltage in public grids],” Warsaw, Poland, 2014. (In Polish).-
dcterms.referencesY. Rudyk, O. Nazarovets, I. Holovatchuk, Current approaches in the system lightning protection arrangement of buildings in view of fire hazard and personal risk, Pozhezhna bezpeka, no.33, pp. 88-94, 2018. DOI:10.32447/20786662.33.2018.12.-
dcterms.referencesA.G. Ryzhevskii, and D.V. Shabalov, Avtomatizatsiya kontrolya formy monoimpul'snykh signalov [Automation of the monopulse signals form control]. Moskow, USSR, 1986. (In Russian).-
dcterms.referencesR. Lappe, and F. Fisher, Izmerenia v energeticheskoy electronice [Measurements in power electronics]. Moskow, USSR, 1986. (In Russian).-
dcterms.referencesV.V. Nosov, “Promyshlennye pomekhi i obespechenie nadezhnosti funktsionirovaniya sistem upravleniya tekhnologicheskim protsessami [Industrial interference and ensuring the reliability of the operation of process control systems].” Izmereniya, kontrol, avtomatizatsiya, no.2. pp.61-71, 1987. (In Russian)-
dcterms.referencesF. H. Silveira; and S. Visacro, “Calculation of the Lightning Performance of Transmission Lines: A Study of the Impact of Current Waveform and Front Time,” in Proceedings of the 33th International Conference on Lightning Protection (ICLP), Estoril, Portugal, 2016.-
dcterms.referencesV.M. Vanko Sposib vyyavlennya ta vymiryuvannya parametriv yakosti impul'snoyi napruhy elektrychnoyi merezhi. [A method for detecting and measuring the quality parameters of the pulse voltage of the electric network] Vidbir ta obrobka informatsiyi, no.23, pp.69-74, 2005. (In Ukrainian).-
dcterms.referencesV.M. Vanko, Patent of Ukraine №72638. Digital active currence network voltmeter, Bulletin of inventions, no.3, 2005. (In Ukrainian)-
dcterms.referencesV.I. Hudym, B.M.Yurkiv, and O.B. Nazarovets, Mathematical modeling of the processes of heating in conductors of internal electrical networks in housing and public buildings, Pozhezhna bezpeka, no.26, pp. 59-64, 2016. (In Ukrainian).-
Appears in Collections:2020

Files in This Item:
File Description SizeFormat 
PiCST19_130_v3.pdfConference paper759.22 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.