Please use this identifier to cite or link to this item: https://sci.ldubgd.edu.ua/jspui/handle/123456789/19246
Full metadata record
DC FieldValueLanguage
dc.contributor.authorParkhomenko, Volodymyr-Petro-
dc.contributor.authorMykhalichko, Borys-
dc.contributor.authorLavrenyuk, Helen-
dc.contributor.authorHodovanets, Nadiia-
dc.contributor.authorMykhalichko, Oleg-
dc.date.accessioned2026-10-21T09:31:43Z-
dc.date.available2026-10-21T09:31:43Z-
dc.date.issued2027-
dc.identifier.urihttps://doi.org/10.1016/j.firesaf.2026.104979-
dc.identifier.urihttps://sci.ldubgd.edu.ua/jspui/handle/123456789/19246-
dc.description.abstractThis study investigates the fire suppression efficiency and multi-action mechanisms of a novel binary aqueous fire-extinguishing agent (AFEA) consisting of 50 wt% ammonium carbonate (NH4)2CO3 in an aqueous ammonia medium. Open-air fire tests were conducted using a specialized automated spray installation against standard Class 8B petrol and diesel fuel pool fires. The experimental results demonstrated that the (NH4)2CO3-based AFEA spray achieved a rapid knockdown of volatile A-92 petrol fires within 2.0 s, requiring a minimal consumed volume of 280 ± 6 mL and outperforming the reference 40 wt% K2CO3 solution four-fold. Furthermore, the proposed formulation was the only agent capable of successfully suppressing high-thermal-inertia Euro-5 diesel fuel fires within a mean time of 29.7 ± 0.6 s under open-space constraints, where conventional salt solutions and tap water failed. The performance is governed by a synergistic mechanism: the endothermic pyrolytic breakdown of (NH4)2CO3 inside the flame generates a complex mixture of gases, including carbon dioxide (CO2), water vapor (H2O) that dilute oxygen, while ammonia (NH3) undergoes oxidative reactions in the high-temperature zone, further depleting local oxygen. A preliminary engineering upscaling analysis for a full-scale RVS-400 vertical steel storage tank (57 m2 pool area) indicated that transitioning to this novel binary system could conceptually yield a 75.7% reduction in the required agent inventory (from 391.7 L to 95.4 L). These findings provide a useful technical foundation for the potential development of compact, rapid-response automated fire protection systems for industrial petroleum depots.en_US
dc.language.isoenen_US
dc.publisherFire Safety Journalen_US
dc.relation.ispartofseries167;104979-
dc.subjectAmmonium carbonateen_US
dc.subjectAqueous ammoniaen_US
dc.subjectWater misten_US
dc.subjectClass B firesen_US
dc.subjectFire suppression mechanismen_US
dc.subjectStorage tank upscalingen_US
dc.titleExtinguishing efficiency of an ammonium carbonate-based water mist in an aqueous ammonia medium for class B firesen_US
dc.typeArticleen_US
Appears in Collections:2026

Files in This Item:
File Description SizeFormat 
Extinguishing-efficiency-of-an-ammonium-carbonate-based-wate_2027_Fire-Safet.pdf4.04 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.